EPD-IES-0009343:004

depub_pub_email

asdfasf

General information

EPD OwnerDemo Organisation Test
Registration numberEPD-IES-0009343:004
PCRPCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
StatusExpired
Publication date2025-02-27
Valid until2025-01-27
EN 15804 compliantYes
Geographical scopeAsia

Product images

Programme information

ProgrammeInternational EPD System
AddressEPD International AB Box 210 60 SE-100 31 Stockholm Sweden
Websitewww.environdec.com
E-mailsupport@environdec.com

Product category rules

CEN standard EN 15804 serves as the Core Product Category Rules (PCR)
Product Category Rules (PCR)PCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
PCR review was conducted byPCR review was conducted by: The Technical Committee of the International EPD System. See www.environdec.com for a list of members. Review chair: Claudia A. Peña, University of Concepción, Chile. The review panel may be contacted via the Secretariat www.environdec.com/support.
Complementary Product Category Rules (c-PCR)PCR 2019:14-c-PCR-002 c-PCR-002 Ceramic tiles (EN 17160) (2019-12-20) Version: 1.2.4
c-PCR review was conducted byThe Technical Committee of the International EPD System

Verification

LCA accountabilityDemo EPD Owner, demo@aaa.environdec.com.aaa, Demo Organisation Test
Independent third-party verification of the declaration and data, according to ISO 14025:2006, via
Third-party verifierDemo Verifier (Demo Verifier)
Approved byInternational EPD System
Procedure for follow-up of data during EPD validity involves third party verifier
*EPD Process Certification involves an accredited certification body certifying and periodically auditing the EPD process and conducting external and independent verification of EPDs that are regularly published. More information can be found in the General Programme Instructions on www.envrondec.com.

Ownership and limitation on use of EPD

Limitations

EPDs within the same product category but registered in different EPD programmes may not be comparable. For two EPDs to be comparable, they shall be based on the same PCR (including the same version number up to the first two digits) or be based on fully-aligned PCRs or versions of PCRs; cover products with identical functions, technical performances and use (e.g. identical declared/functional units); have equivalent system boundaries and descriptions of data; apply equivalent data quality requirements, methods of data collection, and allocation methods; apply identical cut-off rules and impact assessment methods (including the same version of characterisation factors); have equivalent content declarations; and be valid at the time of comparison.

Ownership

The EPD Owner has the sole ownership, liability, and responsibility for the EPD.

Information about EPD Owner

EPD OwnerDemo Organisation Test
Contact person nameqwer
Contact person e-mailsnem
Organisation addressArmenia City 123 Valhallavägen 81 SE-114 27 Stockholm Address line 2

Description of the organisation of the EPD Owner

werqwr

Organisation logo

Product information

Product namedoemn
Product identificationsadfaas
Product descriptionasdfasf
Technical purpose of productsadffd
Manufacturing or service provision descriptionasdfsadfsdf
Material propertiesArea density (kg/m2), 4
Production siteAlbania tirana 53423
UN CPC code011. Cereals
Geographical scopeAsia
Hazardous and toxic substancesThe product does not contain any substances from the SVHC candidate list in concentrations exceeding 0.1% of its weight.

Technical characteristics and performance

c-PCR-002: Ceramic tiles

Product nameBrandsGroup (EN 14411:2016)Model/sizeCodeLevel of representatives of the data
sdfasdfasdfasdfasfasf

Content declaration

Product content
Content nameWeight, kgPost-consumer recycled material, weight-% of productBiogenic material, weight-% of productBiogenic material1, kg C/declared unit or product
sdf33333
Total33333
Note11 kg biogenic carbon is equivalent to 44/12 kg of CO2
Packaging materials
Material nameWeight, kgWeight-% (versus the product)Biogenic material1, kg C/declared unit or product
wre2336
Total2336
Note11 kg biogenic carbon is equivalent to 44/12 kg of CO2

LCA information

EPD based on declared or functional unitDeclared unit
Declared unit and reference flowwerwerqwrewerweqr Area (m2), 33
Conversion factor to mass3
Are infrastructure or capital goods included in any upstream, core or downstream processes?
Datasources used for this EPD
LCA SoftwareSimaPro SimaPro 9.3
Version of the EN 15804 reference packageEF Reference Package 3.0
Technology description including background systemqweqwe
Scrap (recycled material) inputs contribution levelLess than 10% of the GWP-GHG results in modules A1-A3 come from scrap inputs
Electricity data
Electricity used in the manufacturing process in A3
Type of electricity mixSpecific electricity mix as generated, or purchased from an electricity supplier, demonstrated by a contractual instrument
Energy sourcesHydro4%
Wind2%
Solar33%
Biomass5%
Geothermal6%
Waste7%
Nuclear4%
Natural gas3%
Coal3%
Oil4%
Peat6%
Other7%
GWP-GHG intensity (kg CO2 eq./kWh)33 kg CO2 eq./kWh

System boundary

Description of the system boundaryCradle to gate with modules C1-C4 and module D (A1-A3 + C + D).
Excluded modulesNo, there is no excluded module, or there are no excluded modules

Declared modules

Product stageConstruction process stageUse stageEnd of life stageBeyond product life cycle
Raw material supplyTransportManufacturingTransport to siteConstruction installationUseMaintenanceRepairReplacementRefurbishmentOperational energy useOperational water useDe-construction demolitionTransportWaste processingDisposalReuse-Recovery-Recycling-potential
ModuleA1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Modules declaredXXXXNDNDNDNDNDNDNDNDXXXXX
GeographyAsiaAsiaAsiaAsiaN/AN/AN/AN/AN/AN/AN/AN/AAsiaAsiaAsiaAsiaAsia
Share of specific data3%--------------
Variation - products3%--------------
Variation - sites3%--------------

Scenarios

Name of the default scenario234
Description of the default scenario234

Module A4: Transport to the building site

Explanatory name of the default scenario in module A4asdfasfd
Brief description of the default scenario in module A4234
Module A4 informationValueUnit
Distance
3
kg/m3
Capacity utilization (including empty returns)
3
km
Bulk density of transported products
3
km
Volume capacity utilization factor
(factor: =1 or <1 or ≥1 for compressed or
nested packaged products)
5
kg/m3
gdsf55
kg/m3

Module C: End-of-life

Explanatory name of the default scenario in module C345eetrrdg
Brief description of the default scenario in module Csdfgsdg
Module C informationValueUnit
fdsaasdf
kg/m3
asdfasdf
kg/m3
adsfasff
%
sdfasdf
kg/m3
sdfsdf
kg/m3
sdfsdf
N/A
asdfasdf
%

Module D: Beyond product life cycle

Explanatory name of the default scenario in module Dertw
Brief description of the default scenario in module Dwertwerrt
Module D informationValueUnit
43212334
%

Results

Mandatory environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - totalGWP-totalkg CO2 eq.6.77E+23.02E+1NDNDNDNDNDNDNDND4.29E+05.19E+02.44E+13.65E-11.70E+1
Climate change - fossilGWP-fossilkg CO2 eq.4.97E+02.29E-2NDNDNDNDNDNDNDND3.35E-23.99E-31.35E-92.09E-4-1.63E-1
Climate change - biogenicGWP-biogenickg CO2 eq.2.17E-11.43E-2NDNDNDNDNDNDNDND4.14E-32.44E-33.57E-22.20E-4-2.57E-3
Climate change - land use and land-use changeGWP-luluckg CO2 eq.6.82E+23.02E+1NDNDNDNDNDNDNDND4.33E+05.20E+02.44E+13.65E-11.68E+1
Ozone depletionODPkg CFC-11 eq.1.42E-56.58E-7NDNDNDNDNDNDNDND8.91E-81.14E-73.87E-71.06E-84.43E-7
AcidificationAPmol H+ eq.2.33E+01.09E-1NDNDNDNDNDNDNDND2.28E-21.75E-22.73E-12.75E-35.49E-2
Eutrophication aquatic freshwaterEP-freshwaterkg P eq.1.35E-12.14E-3NDNDNDNDNDNDNDND1.15E-33.69E-41.44E-23.04E-58.08E-3
Eutrophication aquatic marineEP-marinekg N eq.5.75E-13.69E-2NDNDNDNDNDNDNDND7.92E-36.05E-36.37E-21.05E-31.42E-2
Eutrophication terrestrialEP-terrestrialmol N eq.5.65E+03.91E-1NDNDNDNDNDNDNDND8.37E-26.39E-27.11E-11.13E-21.54E-1
Photochemical ozone formationPOCPkg NMVOC eq.2.38E+01.63E-1NDNDNDNDNDNDNDND2.81E-22.72E-22.13E-13.93E-39.96E-2
Depletion of abiotic resources - minerals and metalsADP-minerals&metals1kg Sb eq.2.58E-38.09E-5NDNDNDNDNDNDNDND2.05E-51.40E-51.50E-35.06E-7-2.32E-5
Depletion of abiotic resources - fossil fuelsADP-fossil1MJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
Water useWDP1m3 world eq. deprived2.04E+22.10E+0NDNDNDNDNDNDNDND4.54E-13.63E-14.01E+04.01E-19.66E-1
AcronymsGWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
General disclaimerIt is discouraged to use the results of modules A1-A3 without considering the results of module C.
Disclaimer 1The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator

Additional mandatory environmental performance indicators

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - GWP-GHGGWP-GHG1kg CO2 eq.6.79E+23.02E+1NDNDNDNDNDNDNDND4.30E+05.20E+02.45E+13.65E-11.70E+1
AcronymsGWP-GHG = Global warming potential greenhouse gas.
General disclaimerIt is discouraged to use the results of modules A1-A3 without considering the results of module C.
Disclaimer 1The GWP-GHG indicator is termed GWP-IOBC/GHG in the ILCD+EPD+ data format. The indicator accounts for all greenhouse gases except biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. As such, the indicator is identical to GWP-total except that the CF for biogenic CO2 is set to zero.

Resource use indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value6.67E+26.43E+0NDNDNDNDNDNDNDND5.30E+01.11E+05.12E+17.69E-2-7.88E+0
PERMMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PERTMJ, net calorific value6.67E+26.43E+0NDNDNDNDNDNDNDND5.30E+01.11E+05.12E+17.69E-2-7.88E+0
PENREMJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
PENRMMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PENRTMJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
SMkg9.57E+20.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
RSFMJ, net calorific value9.12E+10.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
NRSFMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
FWm35.54E+06.89E-2NDNDNDNDNDNDNDND2.40E-21.19E-21.64E-19.65E-33.92E-4
AcronymsPERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.
General disclaimerIt is discouraged to use the results of modules A1-A3 without considering the results of module C.

Waste indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg3.25E+02.73E-3NDNDNDNDNDNDNDND3.34E-44.72E-41.83E-34.81E-52.37E-3
NHWDkg4.56E+23.84E+1NDNDNDNDNDNDNDND2.81E+06.66E+09.50E+26.00E+1-2.43E+0
RWDkg1.03E-21.34E-4NDNDNDNDNDNDNDND1.65E-42.32E-56.69E-41.34E-6-3.70E-4
AcronymsHWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed.
General disclaimerIt is discouraged to use the results of modules A1-A3 without considering the results of module C.

Output flow indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
CRUkg0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
MFRkg1.73E+20.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+09.40E+20.00E+00.00E+0
MERkg0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EEEMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EETMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
AcronymsCRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy.
General disclaimerIt is discouraged to use the results of modules A1-A3 without considering the results of module C.

Additional information

Version history

Test

References

ewfw