EPD-IES-0009472:002

YuTest 2402_PC (dates)

test

General information

EPD Owner!!!demo111
Registration numberEPD-IES-0009472:002
PCRPCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
StatusValid
Publication date2025-02-24
Valid until2029-02-25
EN 15804 compliantYes
Geographical scopeAfrica

Product images

Programme information

ProgrammeInternational EPD System
AddressEPD International AB Box 210 60 SE-100 31 Stockholm Sweden
Websitewww.environdec.com
E-mailsupport@environdec.com

Product category rules

CEN standard EN 15804 serves as the Core Product Category Rules (PCR)
Product Category Rules (PCR)PCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
PCR review was conducted byPCR review was conducted by: The Technical Committee of the International EPD System. See www.environdec.com for a list of members. Review chair: Claudia A. Peña, University of Concepción, Chile. The review panel may be contacted via the Secretariat www.environdec.com/support.

Verification

LCA accountabilityMerve Akkaya, .aaa, !!!demo111
Independent third-party verification of the declaration and data, according to ISO 14025:2006, via
EPD process certificate issued byBuilding Research Institute – Certification Company, Ltd (Výzkumný ústav pozemních staveb Certifikační společnost, s.r.o.)
Accredited byCzech Accreditation Institute
Accredited certification body addressCzech Republic
Procedure for follow-up of data during EPD validity involves third party verifier
*EPD Process Certification involves an accredited certification body certifying and periodically auditing the EPD process and conducting external and independent verification of EPDs that are regularly published. More information can be found in the General Programme Instructions on www.envrondec.com.

Ownership and limitation on use of EPD

Limitations

EPDs within the same product category but registered in different EPD programmes may not be comparable. For two EPDs to be comparable, they shall be based on the same PCR (including the same version number up to the first two digits) or be based on fully-aligned PCRs or versions of PCRs; cover products with identical functions, technical performances and use (e.g. identical declared/functional units); have equivalent system boundaries and descriptions of data; apply equivalent data quality requirements, methods of data collection, and allocation methods; apply identical cut-off rules and impact assessment methods (including the same version of characterisation factors); have equivalent content declarations; and be valid at the time of comparison.

Ownership

The EPD Owner has the sole ownership, liability, and responsibility for the EPD.

Information about EPD Owner

EPD Owner!!!demo111
Contact person nameDemo EPD Owner
Contact person e-maildemo@aaa.environdec.com.aaa
Organisation addressNew Zealand test 129889 test address

Description of the organisation of the EPD Owner

test

Organisation logo

Product information

Product nameTest
Product identificationtest
Product descriptiontest
Technical purpose of producttest
Manufacturing or service provision descriptiontest
Material propertiesCompressive strength (MPa), 44
Production siteAngola test 09876
UN CPC code011. Cereals
GTIN12121212
Geographical scopeAfrica
Hazardous and toxic substancesThe product does not contain any substances from the SVHC candidate list in concentrations exceeding 0.1% of its weight.

Content declaration

Explanation why content declaration is not relevant

test

LCA information

EPD based on declared or functional unitDeclared unit
Declared unit and reference flowtest Length (m), 12
Conversion factor to mass7
Are infrastructure or capital goods included in any upstream, core or downstream processes?
Datasources used for this EPD
LCA SoftwareOpenLCA OpenLCA 1.7.3
Version of the EN 15804 reference packageEF Reference Package 3.0
Technology description including background systemtest
Scrap (recycled material) inputs contribution levelLess than 10% of the GWP-GHG results in modules A1-A3 come from scrap inputs
Electricity data
Electricity used in the manufacturing process in A3
Type of electricity mixSpecific electricity mix as generated, or purchased from an electricity supplier, demonstrated by a contractual instrument
Energy sourcesHydro0.97%
Wind4%
Solar5%
Biomass6%
Geothermal8%
Waste0%
Nuclear1%
Natural gas2%
Coal0%
Oil0%
Peat0%
Other9%
GWP-GHG intensity (kg CO2 eq./kWh)8 kg CO2 eq./kWh

System boundary

Description of the system boundaryCradle to gate with modules C1-C4 and module D (A1-A3 + C + D).
Excluded modulesNo, there is no excluded module, or there are no excluded modules

Declared modules

Product stageConstruction process stageUse stageEnd of life stageBeyond product life cycle
Raw material supplyTransportManufacturingTransport to siteConstruction installationUseMaintenanceRepairReplacementRefurbishmentOperational energy useOperational water useDe-construction demolitionTransportWaste processingDisposalReuse-Recovery-Recycling-potential
ModuleA1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Modules declaredXXXXNDNDNDNDNDNDNDNDXXXXX
GeographyAsiaEuropeGlobalAfricaAsiaN/AN/AN/AN/AN/AN/AN/AGlobalAfricaEuropeAfricaAfrica
Share of specific data45%------------
Variation - products6%------------
Variation - sites77%------------

Scenarios

Name of the default scenario1
Description of the default scenariotest

Module A4: Transport to the building site

Explanatory name of the default scenario in module A4test
Brief description of the default scenario in module A4test
Description of the default scenario in module A4test

Module C: End-of-life

Explanatory name of the default scenario in module Ctest
Brief description of the default scenario in module Ctest
Description of the default scenario in module Ctest

Module D: Beyond product life cycle

Explanatory name of the default scenario in module Dtest
Brief description of the default scenario in module Dtest
Description of the default scenario in module Dtest

Results

Mandatory environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - totalGWP-totalkg CO2 eq.6.77E+23.02E+1NDNDNDNDNDNDNDND4.29E+05.19E+02.44E+13.65E-11.70E+1
Climate change - fossilGWP-fossilkg CO2 eq.4.97E+02.29E-2NDNDNDNDNDNDNDND3.35E-23.99E-31.35E-92.09E-4-1.63E-1
Climate change - biogenicGWP-biogenickg CO2 eq.2.17E-11.43E-2NDNDNDNDNDNDNDND4.14E-32.44E-33.57E-22.20E-4-2.57E-3
Climate change - land use and land-use changeGWP-luluckg CO2 eq.6.82E+23.02E+1NDNDNDNDNDNDNDND4.33E+05.20E+02.44E+13.65E-11.68E+1
Ozone depletionODPkg CFC-11 eq.1.42E-56.58E-7NDNDNDNDNDNDNDND8.91E-81.14E-73.87E-71.06E-84.43E-7
AcidificationAPmol H+ eq.2.33E+01.09E-1NDNDNDNDNDNDNDND2.28E-21.75E-22.73E-12.75E-35.49E-2
Eutrophication aquatic freshwaterEP-freshwaterkg P eq.1.35E-12.14E-3NDNDNDNDNDNDNDND1.15E-33.69E-41.44E-23.04E-58.08E-3
Eutrophication aquatic marineEP-marinekg N eq.5.75E-13.69E-2NDNDNDNDNDNDNDND7.92E-36.05E-36.37E-21.05E-31.42E-2
Eutrophication terrestrialEP-terrestrialmol N eq.5.65E+03.91E-1NDNDNDNDNDNDNDND8.37E-26.39E-27.11E-11.13E-21.54E-1
Photochemical ozone formationPOCPkg NMVOC eq.2.38E+01.63E-1NDNDNDNDNDNDNDND2.81E-22.72E-22.13E-13.93E-39.96E-2
Depletion of abiotic resources - minerals and metalsADP-minerals&metals1kg Sb eq.2.58E-38.09E-5NDNDNDNDNDNDNDND2.05E-51.40E-51.50E-35.06E-7-2.32E-5
Depletion of abiotic resources - fossil fuelsADP-fossil1MJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
Water useWDP1m3 world eq. deprived2.04E+22.10E+0NDNDNDNDNDNDNDND4.54E-13.63E-14.01E+04.01E-19.66E-1
AcronymsGWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
General disclaimerIt is discouraged to use the results of modules A1-A5 without considering the results of module C.
Disclaimer 1The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator

Additional mandatory environmental performance indicators

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - GWP-GHGGWP-GHG1kg CO2 eq.6.79E+23.02E+1NDNDNDNDNDNDNDND4.30E+05.20E+02.45E+13.65E-11.70E+1
AcronymsGWP-GHG = Global warming potential greenhouse gas.
General disclaimerIt is discouraged to use the results of modules A1-A5 without considering the results of module C.
Disclaimer 1The GWP-GHG indicator is termed GWP-IOBC/GHG in the ILCD+EPD+ data format. The indicator accounts for all greenhouse gases except biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. As such, the indicator is identical to GWP-total except that the CF for biogenic CO2 is set to zero.

Resource use indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value6.67E+26.43E+0NDNDNDNDNDNDNDND5.30E+01.11E+05.12E+17.69E-2-7.88E+0
PERMMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PERTMJ, net calorific value6.67E+26.43E+0NDNDNDNDNDNDNDND5.30E+01.11E+05.12E+17.69E-2-7.88E+0
PENREMJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
PENRMMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
PENRTMJ, net calorific value8.47E+34.41E+2NDNDNDNDNDNDNDND6.83E+17.59E+13.30E+29.09E+01.41E+2
SMkg9.57E+20.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
RSFMJ, net calorific value9.12E+10.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
NRSFMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
FWm35.54E+06.89E-2NDNDNDNDNDNDNDND2.40E-21.19E-21.64E-19.65E-33.92E-4
AcronymsPERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.
General disclaimerIt is discouraged to use the results of modules A1-A5 without considering the results of module C.

Waste indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg3.25E+02.73E-3NDNDNDNDNDNDNDND3.34E-44.72E-41.83E-34.81E-52.37E-3
NHWDkg4.56E+23.84E+1NDNDNDNDNDNDNDND2.81E+06.66E+09.50E+26.00E+1-2.43E+0
RWDkg1.03E-21.34E-4NDNDNDNDNDNDNDND1.65E-42.32E-56.69E-41.34E-6-3.70E-4
AcronymsHWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed.
General disclaimerIt is discouraged to use the results of modules A1-A5 without considering the results of module C.

Output flow indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
CRUkg0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
MFRkg1.73E+20.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+09.40E+20.00E+00.00E+0
MERkg0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EEEMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
EETMJ, net calorific value0.00E+00.00E+0NDNDNDNDNDNDNDND0.00E+00.00E+00.00E+00.00E+00.00E+0
AcronymsCRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy.
General disclaimerIt is discouraged to use the results of modules A1-A5 without considering the results of module C.

Additional information

Version history

Editorial UPD

References

test

  • 1, 2
  • 3