EPD-IES-0009512:002

Test LCA 2

1

General information

EPD OwnerDemo Organisation Test
Registration numberEPD-IES-0009512:002
PCRPCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
StatusExpired
Publication date2025-03-11
Valid until2025-03-31
EN 15804 compliantYes
Geographical scopeGlobal

Product images

Programme information

ProgrammeInternational EPD System
AddressEPD International AB Box 210 60 SE-100 31 Stockholm Sweden
Websitewww.environdec.com
E-mailsupport@environdec.com

Product category rules

CEN standard EN 15804 serves as the Core Product Category Rules (PCR)
Product Category Rules (PCR)PCR 2019:14 Construction products (EN 15804:A2) (1.2.4)
PCR review was conducted byPCR review was conducted by: The Technical Committee of the International EPD System. See www.environdec.com for a list of members. Review chair: Claudia A. Peña, University of Concepción, Chile. The review panel may be contacted via the Secretariat www.environdec.com/support.
Complementary Product Category Rules (c-PCR)PCR 2019:14-c-PCR-001 c-PCR-001 Cement and building lime (EN 16908) (2022-05-18) Version: 1.2.4
c-PCR review was conducted byThe Technical Committee of the International EPD System

Verification

LCA accountabilityDemo EPD Owner, demo@aaa.environdec.com.aaa, Demo Organisation Test
Independent third-party verification of the declaration and data, according to ISO 14025:2006, via
EPD process certificate issued byTest Company 4
Accredited byTest VerifierName
Accredited certification body addressUkraine
Procedure for follow-up of data during EPD validity involves third party verifier
*EPD Process Certification involves an accredited certification body certifying and periodically auditing the EPD process and conducting external and independent verification of EPDs that are regularly published. More information can be found in the General Programme Instructions on www.envrondec.com.

Ownership and limitation on use of EPD

Limitations

EPDs within the same product category but registered in different EPD programmes may not be comparable. For two EPDs to be comparable, they shall be based on the same PCR (including the same version number up to the first two digits) or be based on fully-aligned PCRs or versions of PCRs; cover products with identical functions, technical performances and use (e.g. identical declared/functional units); have equivalent system boundaries and descriptions of data; apply equivalent data quality requirements, methods of data collection, and allocation methods; apply identical cut-off rules and impact assessment methods (including the same version of characterisation factors); have equivalent content declarations; and be valid at the time of comparison.

Ownership

The EPD Owner has the sole ownership, liability, and responsibility for the EPD.

Information about EPD Owner

EPD OwnerDemo Organisation Test
Contact person nameAlexandr Berednikov
Contact person e-mailalexandr.berednikov@sigma.software
Organisation addressArmenia City 17 123 Valhallavägen 81 SE-114 27 Stockholm Address line 2 and next

Description of the organisation of the EPD Owner

1

Organisation logo

Product information

Product name1
Product identification1
Product description1
Technical purpose of product1
Manufacturing or service provision description1
Material propertiesArea density (kg/m2), 1
Production site1 Albania 1 11122
UN CPC codeNo applicable UN CPC code
Geographical scopeGlobal
Hazardous and toxic substancesThe product does not contain any substances from the SVHC candidate list in concentrations exceeding 0.1% of its weight.

Content declaration

Product content
Content nameWeight, kgPost-consumer recycled material, weight-% of productBiogenic material, weight-% of productBiogenic material1, kg C/declared unit or product
11111
Total1111
Note11 kg biogenic carbon is equivalent to 44/12 kg of CO2
Packaging materials
Material nameWeight, kgWeight-% (versus the product)Biogenic material1, kg C/declared unit or product
2222
Total222
Note11 kg biogenic carbon is equivalent to 44/12 kg of CO2

LCA information

EPD based on declared or functional unitDeclared unit
Declared unit and reference flow1 Area (m2), 1
Conversion factor to mass1
Are infrastructure or capital goods included in any upstream, core or downstream processes?
Datasources used for this EPD
LCA SoftwareSimaPro SimaPro 9.5
Version of the EN 15804 reference packageEF Reference Package 3.1
Technology description including background system1
Scrap (recycled material) inputs contribution levelLess than 10% of the GWP-GHG results in modules A1-A3 come from scrap inputs
Electricity data
Electricity used in the manufacturing process in A3
Type of electricity mixSpecific electricity mix as generated, or purchased from an electricity supplier, demonstrated by a contractual instrument
Energy sourcesHydro1%
Wind1%
Solar1%
Biomass1%
Geothermal1%
Waste1%
Nuclear1%
Natural gas1%
Coal1%
Oil1%
Peat1%
Other1%
GWP-GHG intensity (kg CO2 eq./kWh)1 kg CO2 eq./kWh
CO2 uptake associated with carbonation and its assumptions
Production stage (module A)Excluded
Use stage (module B)Excluded
End-of-Life stage (module C)Excluded
Beyond product life cycle (Module D)Excluded

System boundary

Description of the system boundaryCradle to gate with modules C1-C4 and module D (A1-A3 + C + D).
Excluded modulesNo, there is no excluded module, or there are no excluded modules

Declared modules

Product stageConstruction process stageUse stageEnd of life stageBeyond product life cycle
Raw material supplyTransportManufacturingTransport to siteConstruction installationUseMaintenanceRepairReplacementRefurbishmentOperational energy useOperational water useDe-construction demolitionTransportWaste processingDisposalReuse-Recovery-Recycling-potential
ModuleA1A2A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Modules declaredXXXXNDNDNDNDNDNDNDNDNDNDNDNDND
GeographyGlobalAfricaAsiaGlobalN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
Share of specific data1%--------------
Variation - products1%--------------
Variation - sites1%--------------

Scenarios

Name of the default scenario1
Description of the default scenario1

Module A4: Transport to the building site

Explanatory name of the default scenario in module A41
Brief description of the default scenario in module A41
Description of the default scenario in module A41

Results

Mandatory environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - totalGWP-totalkg CO2 eq.6.61E+00.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Climate change - fossilGWP-fossilkg CO2 eq.7.64E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Climate change - biogenicGWP-biogenickg CO2 eq.-1.04E+00.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Climate change - land use and land-use changeGWP-luluckg CO2 eq.1.33E-23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Ozone depletionODPkg CFC-11 eq.2.58E-73.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcidificationAPmol H+ eq.3.36E-23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Eutrophication aquatic freshwaterEP-freshwaterkg P eq.3.34E-43.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Eutrophication aquatic marineEP-marinekg N eq.9.36E-33.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Eutrophication terrestrialEP-terrestrialmol N eq.6.95E-23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Photochemical ozone formationPOCPkg NMVOC eq.2.65E-23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Depletion of abiotic resources - minerals and metalsADP-minerals&metals1kg Sb eq.2.20E-53.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Depletion of abiotic resources - fossil fuelsADP-fossil1MJ, net calorific value1.23E+23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Water useWDP1m3 world eq. deprived4.92E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcronymsGWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
Disclaimer 1The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator

Additional mandatory environmental performance indicators

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Climate change - GWP-GHGGWP-GHG1kg CO2 eq.7.65E+02.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcronymsGWP-GHG = Global warming potential greenhouse gas.
Disclaimer 1The GWP-GHG indicator is termed GWP-IOBC/GHG in the ILCD+EPD+ data format. The indicator accounts for all greenhouse gases except biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. As such, the indicator is identical to GWP-total except that the CF for biogenic CO2 is set to zero.

Additional voluntary environmental performance indicators according to EN 15804

Impact categoryIndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
Particulate matter emissionsPMDisease incidence1.00E+01.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
Ionizing radiation - human healthIRP1kBq U235 eq.
Eco-toxicity - freshwaterETP-fw2CTUe
Human toxicity - cancer effectsHTP-c2CTUh
Human toxicity - non-cancer effectsHTP-nc2CTUh
Land-use related impacts/soil qualitySQP2Dimensionless
AcronymsPM = Potential incidence of disease due to particulate matter emissions; IRP = Potential human exposure efficiency relative to U235; ETP-fw = Potential comparative toxic unit for ecosystems; HTP-c = Potential comparative toxic unit for humans; HTP-nc = Potential comparative toxic unit for humans; SQP = Potential soil quality index.
Disclaimer 1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
Disclaimer 2The results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator.

Resource use indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
PEREMJ, net calorific value8.31E+13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
PERMMJ, net calorific value7.42E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
PERTMJ, net calorific value9.05E+13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
PENREMJ, net calorific value1.22E+23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
PENRMMJ, net calorific value1.05E-13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
PENRTMJ, net calorific value1.23E+23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
SMkg4.38E-13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
RSFMJ, net calorific value1.12E+13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
NRSFMJ, net calorific value0.00E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
FWm31.20E-13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcronymsPERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

Waste indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
HWDkg1.83E-43.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
NHWDkg7.63E-13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
RWDkg8.88E-53.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcronymsHWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed.

Output flow indicators according to EN 15804

IndicatorUnitA1-A3A4A5B1B2B3B4B5B6B7C1C2C3C4D
CRUkg0.00E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
MFRkg3.46E-23.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
MERkg3.86E-13.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
EEEMJ, net calorific value0.00E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
EETMJ, net calorific value0.00E+03.00E+0NDNDNDNDNDNDNDNDNDNDNDNDND
AcronymsCRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported electrical energy; EET = Exported thermal energy.

Additional information

Version history

123

References

1